Order 100+ units and get a 10% discount!

Lambert-Kay Aorta Anastomosis Clamps

–

Next Edge Surgical LLC

Lambert-Kay aorta anastomosis clamps with 4.5 cm jaw length and 4.5 cm jaw depth. Review the listed dimensions.

Weight100 g
Sizejaw length 4.5cm 1-3/4″ depth 3.2cm 1-1/4″, jaw length 4.5cm 1-3/4″ depth 4.5cm 3/4″

$39.60

SKU: N/A
SKU: N/A

Questions regarding this product? Give us a call or send us an email

Condition
New
Brand Country
USA
Package Quantity
1/pk

Lambert-Kay Aorta Anastomosis Clamps – 10-541-20, 4.5 cm Jaw Length, 4.5 cm Depth

This is the Lambert-Kay Aorta Anastomosis Clamp from Next Edge Surgical LLC. This clamp is used during a Cardiovascular surgical procedure to provide precise clamping during an aorta anastomosis. This model has a jaw length of 4.5cm (1-3/4) with a jaw depth of 4.5cm. This clamp comes in various lengths of jaw depth and can be compared to see which would be best for your situation. This product should only be used by trained professionals.

Designed for Cardiovascular Procedures

Aorta anastomoses clamps are used within cardiovascular procedures to allow for controlled clamping of vessels during certain stages of the procedure. The Lambert-Kay design offers a specific jaw shape. The correct clamp should be selected based on the type of surgical access, nature of vessel and surgeons judgement. The instrument should be placed and applied with care by trained personnel. It should be used in accordance with recognised clinical practice. The information provided here is general information only and should not be used as a substitute for professional training.

4.5 cm Jaw Length and Depth

This clamp is specified as a Lambert/Kay clamp with 4.5cm jaws (approximately 1-3/4″). It also has 4.5cm jaw depth. This can be seen to be different from the other clamp listed, which has a 3.2cm jaw depth. The specification provided does contain the required information that the jaws are 4.5cm but provides no further information on the overall length of the instrument, shape of jaws or material. Any further technical requirements should be confirmed with your supplier prior to purchasing.

Supporting Aortic Anastomosis Procedures

These devices are used to join blood vessels during aortic anastomosis. They allow the surgeon to control blood flow during the correct stages of surgery. The Lambert-Kay Aorta Anastomosis Clamp has been designed for use in professional cardiovascular surgery by an experienced surgeon. This product should be selected and used by the surgeon performing the operation. This instrument should only be used for its intended purpose. Always use this instrument correctly, following your institution’s guidelines.

Healthcare facilities and professionals sourcing related equipment can also explore the Cardiovascular & Thoracic Instruments category at Next Edge Surgical LLC.

Available Jaw Configurations

This product comes in two different depths. The jaw length is 4.5cm (1-3/4″). The 3.2cm (1-1/4″) and 4.5cm have been listed. This information will help professionals choose the correct option based on their instrument selection criteria. As both options are listed together, please make sure you are ordering the correct size. If you need any further information regarding measurements or compatibility, please contact Next Edge Surgical LLC.

Instrument Handling and Care

Before using this device, ensure that it is undamaged, worn, or out of alignment. Ensure that you follow the manufacturer’s guidelines and standard cardiovascular surgery techniques. Ensure that you clean, sterilize, maintain, and store the device according to reliable guidelines. The product does not state what material the device is made from or how it should be sterilized, so please confirm this with your supplier. This device is for use by trained healthcare professionals only.

Product Specifications

SpecificationDetails
Product NameLambert-Kay Aorta Anastomosis Clamp
Brand / SupplierNext Edge Surgical LLC
Product Number10-541-20
Instrument TypeCardiovascular surgical clamp
Intended ApplicationAortic anastomosis procedures
Selected Jaw Length4.5 cm / 1-3/4 inches
Selected Jaw Depth4.5 cm
Other Available Jaw Depth3.2 cm / 1-1/4 inches
Weight100 g
Price$39.60
SKUN/A in supplied listing
Overall Instrument LengthNot specified
MaterialNot specified
Product URLLambert-Kay Aorta Anastomosis Clamp – 10-541-20

Key Features

FeatureDescription
Lambert-Kay DesignIntended for cardiovascular surgical applications
Aortic Anastomosis UseDesigned for selected vascular clamping requirements
4.5 cm Jaw LengthMeasures approximately 1-3/4 inches
4.5 cm Jaw DepthIdentifies the selected configuration
Alternative SizeA 3.2 cm jaw-depth option is also listed
Professional InstrumentIntended for trained healthcare professionals

Frequently Asked Questions

1. What is the Lambert-Kay Aorta Anastomosis Clamp used for?

It is designed for controlled clamping during appropriate cardiovascular and aortic anastomosis procedures.

2. What is the jaw length of this version?

The listed jaw length is 4.5 cm, or approximately 1-3/4 inches.

3. What is the jaw depth of this selected configuration?

This variation has a listed jaw depth of 4.5 cm.

4. Are other jaw-depth options available?

Yes, the listing also includes a 3.2 cm jaw-depth configuration.

5. What is the price of this clamp?

The supplied product listing shows a price of $39.60.

 

 

Reviews

There are no reviews yet.

Be the first to review “Lambert-Kay Aorta Anastomosis Clamps”